Short Description:

Economic 3-digit Single-loop Digital Display Controller is in modular structure, easily operable, cost-effective, applicable in light industry machinery, ovens, laboratory equipment, heating/cooling and other objects in the temperature range of 0~999 °C. Features Double four-digit LED display;5 types of dimensions available;Standard snap-in installation;Power supply: AC/DC100~240V (Frequency50/60Hz) Power consumption≤5W; DC 12~36V Power consumption≤3W


Product Detail

Product Tags

  • Specification
 Product Digital Single-loop digital display controller
 Model SUP-110T
 Display Dual-screen LED display
 Dimension C. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F. 72*72*110mm
H. 48*48*110mm
Measurement accuracy ±0.3%FS
Analog output Analog output—-4-20mA、1-5V(RL≤500Ω)、1-5V(RL≥250kΩ)
Alarm Output With upper and lower limit alarm function, with alarm return difference setting;Relay contact capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistance C load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Power supply AC/DC100~240V (Frequency50/60Hz) Power consumption≤5W
DC 12~36V  Power consumption≤3W
Use environment Operating temperature(-10~50℃)No condensation, no icing
Control precision ±0.5℃

 

  • Introduction

Economic 3-digit Single-loop Digital Display Controller is in modular structure, easily operable, cost-effective, applicable in light industry machinery, ovens, laboratory equipment, heating/cooling and other objects in the temperature range of 0~999 °C. The instrument displays with dual row 3-digit numeric tube, with a variety of RTD/TC input signal types optional with an accuracy of 0.3%; 5 sizes optional, supporting 2 alarm functions, with transmission output. Optical isolation for input terminal, output terminal, a power supply terminal, 100-240V AC/DC or 12-36V DC switching power supply, standard snap-on installation, ambient temperature at 0-50 °C, and the relative humidity of 5-85% RH (no condensation).

Terminal Assignments and Dimensions:

(1) PV display window (measured value)
(2) SV display window
In measurement state, the display is defined by dis in the level-1 parameters; in parameters setting state, it displays the set value.
(3) The first alarm (AL1) and the second alarm (AL2) indicators, running lights (OUT), A/M indicators without effect
(4) Confirm key
(5) Shift key
(6) Down key
(7) Up key

Input signal type list:

Graduation Number Pn Signal type Measure range Graduation Number Pn Signal type Measure range
0 TC B 100~999℃ 5 TC J 0~999℃
1 TC S 0~999℃ 6 TC R 0~999℃
2 TC K 0~999℃ 7 TC N 0~999℃
3 TC E 0~999℃ 11 RTD Cu50 -50~150℃
4 TC T 0~400℃ 14 RTD Pt100 -199~650℃